Computation and field experiment validation of greenhouse energy load using building energy simulation model

Taehwan Ha, In-bok Lee, Kyeong-seok Kwon, Se-Woon Hong

Abstract


Greenhouse Building Energy Simulation (BES) models were developed to estimate the energy load using TRNSYS (ver. 16, University of Wisconsin, USA), a commercial BES program. Validation was conducted based on data recorded during field experiments. The BES greenhouse modeling is reliable, as validation showed 5.2% and 5.5% compared with two field experiments, respectively. As the next step, the heating characteristics of the greenhouses were analyzed to predict the maximum and annual total heating loads based on the greenhouse types and target locations in the Republic of Korea using the validated greenhouse model. The BES-computed results indicated that the annual heating load was greatly affected by the local climate conditions of the target region. The annual heating load of greenhouses located in Chuncheon, the northernmost region, was 44.6% higher than greenhouses in Jeju, the southernmost area among the studied regions. The regression models for prediction of maximum heating load of Venlo type greenhouse and widespan type greenhouse were developed based on the BES computed results to easily predict maximum heating load at field and they explained nearly 95% and 80 % of the variance in the data set used, respectively, with the predictor variables. Then a BES model of geothermal energy system was additionally designed and incorporated into the BES greenhouse model. The feasibility of the geothermal energy system for greenhouse was estimated through economic analysis.
Keywords: greenhouse, building energy simulation (BES), energy load, dynamic analysis, geothermal energy, heating load
DOI: 10.3965/j.ijabe.20150806.2037

Citation: Ha T, Lee I B, Kwon K S, Hong S W. Computation and field experiment validation of greenhouse energy load using Building Energy Simulation model. Int J Agric & Biol Eng, 2015; 8(6): 116-127.

Keywords


greenhouse, building energy simulation (BES), energy load, dynamic analysis, geothermal energy, heating load

Full Text:

PDF

References


Ministry of Agriculture, Food and Rural Affairs (MAFRA). Major statistics data of agriculture, food and rural affairs. 2014; 11-1543000-000128-10. (in Korean)

Hanova J, Dowlatabadi H. Strategic GHG reduction through the use of ground source heat pump technology. Environmental Research Letters, 2007; 2(4): doi: 10.1088/ 1748-9326/2/4/044001.

Ministry of Agriculture, Food and Rural Affairs (MAFRA). 2011 greenhouse status for vegetables and vegetable production records. 2011; 11-1541000-000273-10. (in Korean)

Ministry of Agriculture, Food and Rural Affairs (MAFRA). 2013 greenhouse status for vegetables and vegetable production records, 2013; 11-1543000-000051-10. (in Korean)

Al-ajmi F F, Hanby V I. Simulation of energy consumption for Kuwaiti domestic buildings. Energy and Buildings, 2008; 40(6): 1101–1109.

Terziotti L T, Sweet M L, McLeskey Jr J T. Modeling seasonal solar thermal energy storage in a large urban residential building using TRNSYS 16. Energy and Buildings, 2012; 45: 28–31.

Magnier L, Haghighat F. Multiobjective optimization of building design using TRNSYS simulations, genetic algorithm, and Artificial Neural Network. Building and Environment, 2010; 45: 739–746.

Rodríguez G C, Andrés A C, Muñoz F D, López J M C, Zhang Y. Uncertainties and sensitivity analysis in building energy simulation using macroparameters. Energy and Buildings, 2013; 67: 79–87.

Bhandari M, Shrestha S, New J. Evaluation of weather datasets for building energy simulation. Energy and Buildings. 2012; 49: 109–118.

Saelens D, Parys W, Roofthooft J, de la Torre A T. Assessment of approaches for modeling louver shading devices in building energy simulation programs. Energy and Buildings, 2013; 60: 286–297.

Lehmann B, Güttinger H, Dorer V, van Velsen S, Thiemann A, Frank Th. Eawag Forum Chriesbach—Simulation and measurement of energy performance and comfort in a sustainable office building. Energy and Buildings. 2010; 42: pp. 1958-1967.

Granadeiro V, Duarte J P, Correia J R, Leal V M. Building envelope shape design in early stages of the design process: Integrating architectural design systems and energy simulation. Automation in Construction, 2013; 32: 196–209.

Rahman M M, Rasul M G, Khan M M K. Energy conservation measures in an institutional building in sub-tropical climate in Australia. Applied Energy, 2010; 87(10): 2994–3004.

Tzivanidis C, Antonopoulos K A, Gioti F. Numerical simulation of cooling energy consumption in connection with thermostat operation mode and comfort requirements for the Athens buildings. Applied Energy, 2011; 88(8): 2871–2884.

Zogou O, Stapountzis H. Energy analysis of an improved concept of integrated PV panels in an office building in central Greece. Applied Energy, 2011; 88(3): 853–866.

Hong S W, Lee I B, Hong H K, Seo I H, Hwang H S, Bitog J

P, Yoo J I, Kwon K S, Ha T, Kim K S. Analysis of heating load of a naturally ventilated broiler house using BES simulation. Journal of the Korean Society of Agricultural Engineers, 2008; 50(1): 39–47. (in Korean with English abstract)

Jang J C, Kang E C, Lee E J. Peak cooling and heating load and energy simulation study for a special greenhouse facility. Journal of the Korean Solar Energy Society, 2009; 29(1): 72–76. (in Korean with English abstract)

Akghbashlo M, Müller J, Mobli H, Madadlou A, Rafiee S. Modeling and simulation of deep-bed solar greenhouse drying of chamomile flowers. Drying Technology, 2014; 33: 684–695.

Alvarez-Sánchez E, Leyva-Retureta G, Portilla-Flores E, López-Velázquez A. Evaluation of thermal behavior for an asymmetric greenhouse by means of dynamic simulations. Dyna, 2014; 81(188): 152–159.

Zhang L, Xu P, Mao J C, Tang X. Design and application of a seasonal solar soil heat storage system applied in greenhouse heating. Applied Mechanics and Materials, 2014; 672: 21–25.

Vadiee A, Yaghoubi M, Sardella M, Farjam P. Energy analysis of fuel cell system for commercial greenhouse application–A feasibility study. Energy Conversion and Management, 2015; 89: 925–932.

Ministry of Land, Transport and Maritime Affairs (MLTMA). The standard design of Korea glass greenhouses. 1997. (in Korean)

Bok L S, Analysis and Validation of Dynamic Heat Energy for Greenhouse with Geothermal System using Field Data. MS thesis, Seoul: Seoul National University in Korea, 2012.8, 94p. (in Korea with English abstract)

Flynn C, Sirén K. Influence of location and design on the performance of a solar district heating system equipped with borehole seasonal storage. Renewable Energy, 2015; 81: 377–388.

Rural Development Administration (RDA). Weekly information for farming, 2011; 3.6-3.12. Suwon: National Institute of Agricultural Engineering of RDA. Republic of Korea, 2011. (in Korean)

Doo L B. A study on optimum entering water temperature in vertical closed ground loop heat pump system. MS thesis, Seoul: Hanyang University in Korea, 2009.8; 93p. (in Korean with English abstract)

Park Y, Kim K. A study on the horizontal ground source heat pump greenhouse heating system with thermal storage tank. Journal of Energy Engineering, 2006; 15(3): 194–201.




Copyright (c)